With a cast iron frame, the Y2 three phase motor is a general-purpose motor that can operate at a constant or variable speed while maintaining continuous duty operation (S1) torque throughout a range of speeds.
TECHNICAL DATA
|
Type No. Y2 |
Rated output |
Rated Current |
Rated speed (r/min) |
Rated Current |
Rated speed (r/min) |
EFF % |
Power Factor cosφ |
Rated Torque N.m |
Locked Torque |
Locked Current |
Max Torque |
Noise level Lw dB(A) |
Weight (kg) |
|||||
|
KW |
HP |
IFL 380V A |
IFL 400V A |
IFL 420V A |
IFL 440V A |
IFL 460V A |
IFL 480V A |
Rated Torque TST/TFL |
Rated Torque IST/IFL |
Rated Torque TM/TFL |
||||||||
|
380 - 420V/50Hz |
440 - 480V/60Hz |
|||||||||||||||||
|
Synchronous speed 3000r/min |
||||||||||||||||||
|
Y2 - 63M1 - 2 |
0.18 |
0.25 |
0.53 |
0.50 |
0.48 |
2720 |
0.46 |
0.44 |
0.42 |
3260 |
65.0 |
0.80 |
0.6 |
2.2 |
5.5 |
2.2 |
61 |
7 |
|
Y2 - 63M2 - 2 |
0.25 |
0.37 |
0.69 |
0.66 |
0.62 |
2720 |
0.60 |
0.57 |
0.55 |
3260 |
68.0 |
0.81 |
0.9 |
2.2 |
5.5 |
2.2 |
61 |
8 |
|
Y2 - 71M1 - 2 |
0.37 |
0.55 |
0.99 |
0.94 |
0.90 |
2740 |
0.86 |
0.82 |
0.78 |
3285 |
70.0 |
0.81 |
1.3 |
2.2 |
6.1 |
2.2 |
64 |
10 |
|
Y2 - 71M2 - 2 |
0.55 |
0.75 |
1.4 |
1.33 |
1.27 |
2740 |
1.21 |
1.16 |
1.11 |
3285 |
73.0 |
0.82 |
1.9 |
2.2 |
6.1 |
2.3 |
64 |
11 |
|
Y2 - 80M1 - 2 |
0.75 |
1.0 |
1.83 |
1.74 |
1.66 |
2825 |
1.58 |
1.51 |
1.45 |
3390 |
75.0 |
0.83 |
2.5 |
2.2 |
6.1 |
2.3 |
67 |
15 |
|
Y2 - 80M2 - 2 |
1.1 |
1.5 |
2.61 |
2.48 |
2.36 |
2825 |
2.25 |
2.16 |
2.07 |
3390 |
77.0 |
0.84 |
3.7 |
2.2 |
7.0 |
2.3 |
67 |
16 |
|
Y2 - 90S- 2 |
1.5 |
2.0 |
2.46 |
3.29 |
3.13 |
2840 |
2.99 |
2.86 |
2.74 |
3405 |
79.0 |
0.84 |
5.0 |
2.2 |
7.0 |
2.3 |
72 |
19 |
|
Y2 - 90L- 2 |
2.2 |
3.0 |
4.85 |
4.61 |
4.39 |
2840 |
4.19 |
4.01 |
3.84 |
3405 |
81.0 |
0.85 |
7.4 |
2.2 |
7.0 |
2.3 |
72 |
22 |
|
Y2 - 100L- 2 |
3 |
4.0 |
6.34 |
6.02 |
5.74 |
2870 |
5.48 |
5.24 |
5.02 |
3440 |
83.0 |
0.87 |
10.0 |
2.2 |
7.5 |
2.3 |
76 |
32 |
|
Y2 - 112M- 2 |
4 |
5.5 |
8.20 |
7.79 |
7.42 |
2880 |
7.08 |
6.77 |
6.49 |
3455 |
85.0 |
0.88 |
13.3 |
2.2 |
7.5 |
2.3 |
77 |
39 |
|
Y2 - 132S1 - 2 |
5.5 |
7.5 |
11.1 |
10.5 |
10.0 |
2900 |
9.59 |
9.17 |
8.79 |
3480 |
86.0 |
0.88 |
18.1 |
2.2 |
7.5 |
2.3 |
80 |
58 |
|
Y2 - 132S2 - 2 |
7.5 |
10 |
14.9 |
14.2 |
13.5 |
2900 |
12.9 |
12.3 |
11.8 |
3480 |
87 . 0 |
0.88 |
24 . 7 |
2.2 |
7.5 |
2.3 |
80 |
66 |
|
Y2 - 160M1 - 2 |
11 |
15 |
21.2 |
20.1 |
19.2 |
2930 |
18.3 |
17.5 |
16.8 |
3515 |
88 . 4 |
0.89 |
35 . 9 |
2.2 |
7.5 |
2.3 |
86 |
104 |
|
Y2 - 160M2 - 2 |
15 |
20 |
28.6 |
27.2 |
25.9 |
2930 |
24.7 |
23.6 |
22.6 |
3515 |
89 . 4 |
0.89 |
48 . 6 |
2.2 |
7.5 |
2.3 |
86 |
112 |
|
Y2 - 160L- 2 |
18.5 |
25 |
34.7 |
33.0 |
31.4 |
2930 |
30.0 |
28.7 |
27.5 |
3515 |
90.0 |
0.90 |
60.3 |
2.2 |
7.5 |
2.3 |
86 |
132 |
DUTY CYCLES OF Y2 THREE PHASE MOTOR
S1 Continuous Duty
Operation with a steady load for as long as it takes the machine to achieve thermal equilibrium.
01
S2 Short-Time Duty
Operation with a steady load for an insufficient amount of time to enable the machine to achieve thermal equilibrium. The machine's idle time is sufficient to enable it to cool to room temperature. Short-term operation typically lasts 10, 30, 60, and 90 minutes.
02
S3 Intermittent Periodic Duty
Operation in predetermined cycles while subjected to a continuous, repeating load. For the motor to achieve thermal equilibrium, neither the operating nor the resting periods are sufficiently extended. The initial losses are negligible and have little effect on the temperature increase. At a daily 10-minute cycle, the notional relative starting time values are 15, 25, 40, and 60%.
03
S4 Intermittent Periodic Duty
Operation in predetermined cycles while subjected to a continuous, repeating load. The motor's start has an impact on the temperature increase.
04
S5 Intermittent Periodic Duty
Similar to S4 operation, with the exception that the machine's electronic braking significantly affects the rise in temperature.
05
S6 Continuously Operation With Cyclic Load
Operation that is made up of an ongoing sequence of equal cycles. Every cycle has a fixed load time and is uploaded. The machine cannot reach thermal equilibrium in a single cycle due to the short cycle duration. The relative starting time needs to be supplied in order to specify S6 operation.
06
S7 Intermittent Periodic Duty with Pole Changing
Only pole amplitude modulated motors are capable of this kind of action. In this instance, each pole's definition of operation must include the following information:
- Inertia constant
- Number of starts per hour
- The relative duration of operation
07
Hot Tags: y2 three phase motor, China y2 three phase motor manufacturers, factory, Cast Iron Three Phase Motor, IE2 Electric Motor, IE3 Electric Motor, Inverter Duty Motor, three phase motor, Y2 Three Phase Motor